Self-Contained All-in-One Boyard Compressor Marine Air Conditioner

This self-contained unit, has standard stainless steel, using rivet stainless steel metal structure, and nickel-copper coaxis tube as heat exchanger for sea water side. The fan duct can be roted as required when you install it.The fan blower has advantage such as high static pressure, big air flow and low noise. This self-contai

Featured Products

This self-contained unit, has standard stainless steel, using rivet stainless steel metal structure, and nickel-copper coaxis tube as heat exchanger for sea water side. The fan duct can be roted as required when you install it.The fan blower has advantage such as high static pressure, big air flow and low noise. This self-contained unit has the maximum compact design and better performance. As customer required, we can also provide D-smart control PCB with soft-start function to minimize the starting current.
Self-contained Unit
ModelMS6-E2CMS9-E2CMS12-E2CMS16-E2C
Power supplyPh-V-Hz1Ph/220V/50Hz
CoolingCapacityBTU6,0009,00012,00016,000
Input powerW4307209801,210
Rated currentA2.03.34.55.5
EER 4.13.73.63.9
HeatingCapacityBTU6,50010,00013,30017,700
Input powerW4507701,0001,270
Rated currentA2.13.54.65.8
COP 4.23.83.74.0
Max.currentA3.05.36.88.2
Sea water flowM3/h0.420.640.851.15
Indoor air flowM3/h250630630810
Dehumidification capacityL/h0.71.11.82.1
Noise leveldB(A)≤45≤50≤50≤54
Dimension(L*W*H)mm461X265X283602X375X387601X398X388627X400X433
Control box(L*W*H)mm263X182X95
Net weightKg18273038
Refrigerant type R410a
Fan duct sizemmΦ100Φ150
Sea water pipemmG1/2"-16
Condensed water pipeMmG1/2"-19
Note: A 90 degree turn of the air supply hose will reduce the air volume by more than 25%. When installing, the air pipe should be shortened as much as possible, and the right-angle turn of the air pipe or air duct should be reduced
 
ModelMS24-E2CMS32-E2CMS36-E2CMS30-S1CMS36-S1C
Power supplyPh-V-Hz1Ph/220V/50Hz3Ph/380V/50Hz
CoolingCapacityBTU24,00032,00036,00030,00036,000
Input powerW1,7202,4002,7602,4202,620
Rated currentA7.81112.64.95.2
EER 4.13.93.83.64.0
HeatingCapacityBTU27,50038,40043,90036,30044,300
Input powerW1,9202,8303,3002,7203,120
Rated currentA8.712.8155.25.8
COP 4.24.03.93.94.2
Max.currentA11.71820.25.96.3
Sea water flowM3/h1.72.32.52.12.5
Indoor air flowM3/h1,1501,8001,8001,8501,850
Dehumidification capacityL/h3.14.54.94.24.9
Noise leveldB(A)≤59≤64≤67≤65≤67
Dimension(L*W*H)mm707X433X488756X481X560762X511X560755X480X560760X510X550
Control box(L*W*H)mm410X195X115400X195X105
Net weightKg5666886587
Refrigerant type R410aR22
Fan duct sizemmΦ150Φ200
Sea water pipemmG3/4"-19G1"-25
Condensed water pipeMmG3/4"-25
Note:A 90 degree turn of the air supply hose will reduce the air volume by more than 25%. When installing, the air pipe should be shortened as much as possible, and the right-angle turn of the air pipe or air duct should be reduced


This marine modular chillers are ther most flexible, compact design, and light-weight machines. They are the most reliable and easy-service chiller system for marine use. The single chiller capacity from 36,000 to 180,000btu. Generally it can be combined from 1 to 6 untis to a system with manifold piping system. Our control system can automatic run the units according to the heat load of the indoor fan coil unit. So that it can reduce the energy consumption. This system is widely used for catamaran fast-speed ferry boats. Thanks to the single chillers combining together, this system can back up each other, and provide the most reliable chiller function to the boat.
Single chiller has scroll compressor, 4-way valve, coaxis tube condenser, shell& tube evaporator, high/low pressure valve, pressure gauge, drain-pan combine to a compact&light weight system.
T series has knuring titanium coaxis tube for sea water heat exchanger, good for heavy duty chiller systerm in the real sea water use.


Modular water chiller

Single-compress chiller unit
ModelMWA36-S2C/TMWA48-S2C/TMWA60-S2C/TMWA72-S2C/T
Power supplyPh-V-Hz3Ph/380V/50Hz
CoolingCapacityBTU36,00048,00060,00072,000
Input powerW2,6003,4604,4805,200
Rated currentA4.66.28.09.2
EER 4.04.03.94.0
HeatingCapacityBTU44,50059,30075,00089,000
Input powerW3,2504,3305,7806,500
Rated currentA5.77.610.311.4
COP 4.04.03.84.0
Max.currentA7.49.913.614.8
Sea water flowM3/h2.83.74.75.6
Chilled water flowM3/h2.33.13.84.6
Sea water pipe G1" inner thread
Chilled water pipe G1" inner thread
Condensed water pipeMmG3/4"-25
Noise leveldB(A)≤52≤55≤62≤65
Dimension(L*W*H)mm692X440X535888X415X540888X450X540
Net weightKg8490101107
Refrigerant type R410a
 
ModelMWA90-S2C/TMWA120-S2C/TMWA150-S2C/TMWA180-S2C/T
Power supplyPh-V-Hz3Ph/380V/50Hz
CoolingCapacityBTU90,000120,000150,000180,000
Input powerW6,2309,03010,36012,430
Rated currentA11.816.419.523.4
EER 4.03.94.24.2
HeatingCapacityBTU115,000158,000189,800227,700
Input powerW7,50011,30012,94015,530
Rated currentA13.519.62327.6
COP 4.54.04.34.3
Max.currentA15.423.82934.8
Sea water flowM3/h7.39.311.614
Chilled water flowM3/h5.57.69.511.4
Sea water pipe G1" inner thread
Chilled water pipe G1" inner thread
Condensed water pipeMmG3/4"-25
Noise leveldB(A)≤67≤71≤74≤78
Dimension(L*W*H)mm910X600X6501150X650X820
Net weightKg135158215255
Refrigerant type R410a




Floored Fan Coil Unit
Model MF9-E5AMF12-E5AMF18-E5AMF24-E5AMF36-E5A
Power supplyPh-V-Hz1Ph/220V/50Hz
Cooling capacityBTU9,00012,00018,00024,00036,000
Heating capacityBTU10,00013,10019,80026,70042,000
Max. input powerW140140200360680
Water flowM3/h0.550.771.11.52.2
Air flowM3/h6306308101,1501,800
Water pipemmG3/4"-25
Condensed water pipemmG3/4"-25
Fan duct sizemmΦ150Φ200
Noise leveldB(A)≤50≤50≤54≤59≤67
Net weightKg13.514182533
Dimension(L*W*H)mm512X360X390512X360X440560X380X485580X440X583




Horizontal Fan Coil Unit
Model MF9-E5BMF12-E5BMF18-E5BMF24-E5BMF36-E5BMF48-E5B
Power supplyPh-V-Hz 1Ph/220V/50Hz
Cooling capacityBTU9,00012,00018,00024,00036,00048,000
Heating capacityBTU10,30013,80020,70027,60041,40055,200
Max. input powerW5772108150215253
Water flowM3/h0.550.771.11.52.23.0
Air flowM3/h5106801,0201,3602,0402,380
Wind pressurePa30
Water pipemmG3/4"-25
Condensed water pipemmG3/4" external thread
Noise leveldB(A)≤42≤44≤45≤49≤54≤55
Net weightKg121416253137
Dimension(L*W*H)mm815X465X230915X465X2301095X465X2301425X465X2301725X465X2301985X465X230




Ceiling Cassette Fan Coil Unit
Model MF18-E5EMF24-E5EMF36-E5EMF48-E5E
Power supplyPh-V-Hz 1Ph/220V/50Hz
Cooling capacityBTU18,00024,00036,00048,000
Heating capacityBTU22,00036,00056,00066,000
Max. input powerW76132189220
Water flowM3/h1.11.52.23.0
Air flowM3/h8501,4002,0402,380
Water pipemmG3/4"-25
Condensed water pipemmΦ25
Noise leveldB(A)≤43≤48≤50≤52
Net weightKg21263434
Body dimension(L*W*H)mm710X710X290832X832X290
Panel dimension(L*W*H)mm830X830X30980X980X30




DC compressor, DC fan blower, good for boat without marine generator. DC voltage: 12V/48V/48V
DC Unit
ModelMS3.5-A3AMS3.5-B3AMS7-B3AMS7-C3AMS11-C3A
Power supplyPh-V-HzDC12VDC24VDC24VDC48VDC48V
CoolingCapacityBTU3,5003,5007,0007,00011,000
Input powerW295296560560850
Rated currentA2613262620
EER 3.53.53.83.83.6
HeatingCapacityBTU4,0004,0007,5007,50012,000
Input powerW310310540540890
Rated currentA2713.5252522
COP 3.83.84.04.04.0
Max.currentA3116282824
Sea water flowM3/h0.350.450.460.460.75
Indoor air flowM3/h250250290290760
Dehumidification capacityL/h0.60.60.70.71.6
Noise leveldB(A)≤55≤55≤55≤55≤58
Dimension(L*W*H)mm490X236X282484X236X318598X365X346
Control box(L*W*H)mm252X212X125262X222X125
Net weightKg2020252536
Refrigerant type R134a
Fan duct sizemmΦ100Φ100Φ100Φ100Φ150
Sea water pipemmΦ19
Condensed water pipeMmG1/2"-19


The split marine air conditioner consists of two parts: the outdoor unit and the indoor unit. The indoor unit is light and low in noise. The fan can be installed in a 90-degree rotation according to the cabin conditions. The units use stainless steel sheet metal, corrosion-resistant and high-efficiency nickel-copper heat exchangers, and soft starters can be configured according to customer needs to reduce the current and voltage fluctuations of air conditioning startup.
()Split Type Conedensing Unit(Outdoor Unit)
ModelMC9-E2AMC12-E2AMC18-E2AMC24-E2AMC36-S2A/TMC72-S2A/T
Power supplyPh-V-Hz1Ph/220V/50Hz3Ph/380V/50Hz
Cooling CapacityBTU9,00012,00018,00024,00036,00048,000
Input powerW6208401,0601,2602,6004,300
Rated currentA3.34.56.07.85.58.0
EER 4.24.14.14.14.04.0
HeatingCapacityBTU10,00013,00019,90027,30044,50075,000
Input powerW6308601,1001,5603,2005,780
Rated currentA3.54.66.68.76.39.5
COP 4.43.84.04.24.04.1
Max. currentA4.86.39.010.27.612.2
Sea water flowM3/h0.640.851.21.72.84.7
Sea water pipemmG1/2"-16G3/4"-25G1" inner grooved
Refrigerant type R410a
Connecting pipe 1/4",3/8"1/2",3/8"5/8",3/8"5/8",3/8"5/8",3/8"7/8",3/8"
Dimension(L*W*H)mm397X323X347397X315X387462X322X410472X322X450664X436X495662X436X490
Net weightKg131519276781
Noise leveldB(A)≤50≤50≤50≤50≤55≤55
Condensed water pipemmG1/2"-19G3/4"-25
Note: A 90 degree turn of the air supply hose will reduce the air volume by more than 25%. When installing, the air pipe should be shortened as much as possible, and the right-angle turn of the air pipe or air duct should be reduced


Split Type Indoor Unit
Fan blower can be rotated, stainless steel sheet metal, double drain pan with spill-proof design
Floored Indoor Unit
 
Floored Indoor Unit
ModelMA9-E2AMA12-E2AMA18-E2AMA24-E2AMA36-E2A
Power supplyPh-V-Hz1Ph/220V/50Hz
Cooling capacityBTU9,00012,00018,00024,00036,000
Heating capacityBTU10,00013,30020,10027,50043,900
Input powerW140140200360680
Refrigerant type R410a
Connecting pipe 1/4",3/8"1/2",3/8"5/8",3/8"5/8",3/8"5/8",3/8"
Dimension(L*W*H)mm540X360X390540X350X390540X360X425585X380X4851035X365X405
Indoor airflowM3/h6306308101,1501,260
Noise leveldB(A)≤52≤52≤54≤59≤67
Net weightKg1415192530.5
Fan duct sizemmΦ150
Condensed water pipeMmG3/4"-25
Note:A 90 degree turn of the air supply hose will reduce the air volume by more than 25%. When installing, the air pipe should be shortened as much as possible, and the right-angle turn of the air pipe or air duct should be reduced



Low profile and special double drain pan with spill-proof design, no condensing water leaking, low noise.
Horizontal Indoor Unit
Elegant design, fan blow louver adjustable and moveable. Drain pan produced by one piece molding process. duo-drain pump to make sure the condensing water no spill out.
Ceiling Cassette Indoor Unit
 
 Horizontal Indoor UnitCeiling Cassette Indoor Unit
ModelMA18-E2BMA24-E2BMA36-E2BMA24-E2EMA36-E2E
Power supplyPh-V-Hz1Ph/220V/50Hz
Cooling capacityBTU18,00024,00036,00024,00036,000
Heating capacityBTU20,70027,60041,40027,30042,300
Input powerW108150215132189
Refrigerant type R410a
Connecting pipe 5/8",3/8"
Indoor airflowM3/h1,0201,3602,0401,4002,040
Noise leveldB(A)≤45≤49≤54≤48≤50
Net weightKg17.22631.42634
Body dimension(L*W*H)mm1095X465X2301425X465X2301725X465X230710X710X290832X832X290
Panel dimension(L*W*H) ///830X830X30980X980X30
Condensed water pipeMmG3/4" external thread
Note:A 90 degree turn of the air supply hose will reduce the air volume by more than 25%. When installing, the air pipe should be shortened as much as possible, and the right-angle turn of the air pipe or air duct should be reduced

 

Contact us